Meizhengbio's E-commerce Website: www.mzfoodtest.com
首页 Home Product Biotoxin T-2 Toxin Quantitative Rapid Test Kit

T-2 Toxin Quantitative Rapid Test Kit

Analyte:Mycotoxin

Samples:Grain,feed raw material,some finished feed products.

Specification
96T/Kit
Product introduction
Summary

T2 toxin is a trichothecene mycotoxin initially produced by species of Fusarium. T2 toxin is often found in grains and grain products such as cereals and breads. T2 toxin may act as an anticoagulant at low doses, decreasing fibrinolytic and coagulant signaling pathways. In vivo, T2 toxin alters permeability of the blood-brain barrier (BBB). In the brain and spleen, T2 toxin induces oxidative stress by decreasing levels of glutathione and increasing levels of ROS and lipid peroxidation; it also decreases expression of tissue inhibitor of metalloproteinase 1 (TIMP-1) and increases expression of matrix metalloproteinase 9 (MMP9), TNF-α, IL-1β, and IL-6. In vitro, T2 toxin alters steroidogenesis by inhibiting production of follicular-stimulating hormone (FSH) and progesterone and inhibiting the stimulatory effects of IFG-1.

Intended Use

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of T-2 Toxin and is intended for use in grains, feed materials and feed products. This method is suitable for the rapid on-site test.

Available Product

P/N                         Sensitivity                  LOD                         Sample

JC0686                    -                                0-3000ppb               Grain,feed raw material,some finished feed products.

Precautions
1. Adhere to the instructions of test procedures. 2. Store test kits at 4-30˚C when not in use, and do not use the kits beyond the expiration date. 3. Please don’t touch the membrane on the strips. 4. Remove microwell sealer slightly to prevent the powder from being released from the wells. 5. Avoid direct sunlight and direct blows during testing. 6. Do not re-use pipette tips, test strips or microwells. 7. The unsealed microwells should be used within 1 hour. 8. This test method is just used for rapid screening purpose; if positive results are occurred,please verify them by a quantitative method. 9. Methanol/ Ethanol are flammable. Caution must be taken in its use and storage. 10. Please avoid direct sunlight or blowing when testing. 11. Do not take tap-water, distilled water or deionized water as a negative control. 12. Considering that all materials, containers and devices exposed to the sample are contaminated with toxins, please wear protective gloves and safety glasses while using a kit. 13. The components in this test kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 14. If the sample extract is too alkaline (pH>9) or acid (pH<5), please adjust the pH value of the sample extract to be 6.0-8.0 by using NaOH or HCl (2.0 mol/L) before dilution. 15. Any problem encountered during usage, please contact with the supplier.
More Products
Leaving a message