Meizhengbio's E-commerce Website: www.mzfoodtest.com
首页 Home Product Veterinary Drug Residues Tetracyclines Rapid Test Kit

Tetracyclines Rapid Test Kit

Analyte:Antibiotic Residue

Samples:Milk, Sea Food, Meat, Egg

Specification
96 Test/Kit
Product introduction
Summary

The Tetracyclines Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of tetracyclines in raw cow milk, sea food, meat and egg.

Intended Use

This test is designed for rapid field use or daily control in laboratories.

Available Products

P/N                      LOD                                                                                     Sample                     Remark

JC0426                Chlotetracycline: 14-18μg/kg; others: 10-14μg/kg             Milk                           -

JC0055                Tetracycline: 6-9μg/kg                                                         Milk                           -

MQ09B                40ppb                                                                                  Seafood                     -

MQ09K                40ppb                                                                                  Meat                          -

MQ09U                30ppb                                                                                  Egg                            -


Precautions
1. Adhere to the instructions of test procedures. Do not run more than 8 tests at one time. 2. Store test kits at 2-8˚C when not in use, and do not use the kits beyond the expiration date. 3. Please don’t touch the membrane on the strips. 4. Remove microwell sealer slightly to prevent the powder from being released from the wells. 5. The sample to be tested must be a homogeneous liquid which cannot be agglomerated, fermented, rancid precipitated, etc., and cannot be colostrum. 6. Avoid direct sunlight and direct blows during testing. 7. Do not re-use pipette tips, test strips or microwells. 8. The unsealed microwells should be used within 1 hour. 9. Do not take tap-water, distilled water or deionized water as the negative control. 10. This test method is just used for rapid screening purpose, if positive results are occurred, please verify them by a quantitative method. 11. Considering that all materials, containers and devices exposed to the sample are contaminated with harmful substance,please wear protective gloves and safety glasses while using the kit. 12. The components in this test kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 13. Any problem encountered during usage, please contact with the supplier.
More Products
Leaving a message